Complete set of GGD low-voltage switchgear

Features
  • There are several cooling slot holes on the upper and lower ends of cabinet for fully cooling.
  • High in universal coefficient due to the adoption of universal cabinet.
  • The whole cabinet is artistic and elegant since the cabinet shape and separate dimension are designed according to golden section ratio.
  • The protection grade of cabinet is IP30, the user can choose between IP20-IP40 according to the environmental requirements.
  • The cabinet door is connected with framework by rotary moveable hinge to facilitate installation and the removal.
  • Some electrical appliances can realize closing door operation to facilitate maintenance.
Applicable Place
  • Power users such as power plant, substation and industrial and mining enterprises, and used for electric energy conversion, distribution and control of lighting and distribution equipment.
    Model and technical parameter

Product Details

DOWNLOAD




  • Model Description

  • Features
    • There are several cooling slot holes on the upper and lower ends of cabinet for fully cooling.
    • High in universal coefficient due to the adoption of universal cabinet.
    • The whole cabinet is artistic and elegant since the cabinet shape and separate dimension are designed according to golden section ratio.
    • The protection grade of cabinet is IP30, the user can choose between IP20-IP40 according to the environmental requirements.
    • The cabinet door is connected with framework by rotary moveable hinge to facilitate installation and the removal.
    • Some electrical appliances can realize closing door operation to facilitate maintenance.
  • Conditions of Use
    • Ambient temperature: Maximum temperature: +40℃; Minimum temperature: -15℃
    • Ambient humidity: Daily average relative humidity: ≤95%; Monthly average relative humidity: ≤90%
    • Altitude: ≤1,000m
    • The seismic intensity is ≤8°

  • Technical Parameters


    Model

    Rated voltage (V)

    Rated current (A)

    Rated short-circuit breaking current (kA)

    Rated short-time withstand current (kA/1s)

    Rated peak withstand current (kA)

    GGD1

    380

    A

    1000

    15

    15

    30

    B

    600(630)

    C

    400

    GGD2

    380

    A

    1500(1600)

    30

    30

    63

    B

    1000

    C

    600

    GGD3

    380

    A

    3150

    50

    50

    105

    B

    2500

    C

    2000

    GGD4

    380

    A

    4000

    80

    80

    176

    B

    3150

    C

    2500

Leave A Message