z6com尊龙凯时官网

Combined transformer (American type)

Features
  • Small volume, compact structure, the floor area is only about 1/3-1/5 of that of domestic European box-type substation in the same capacity.
  • Fully insulating structure, safe and reliable.
  • AS13 transformer with low loss and noise and strong overload capacity
  • Flexible and reliable power supply mode, applicable to ring network and terminal.
  • Various low voltage feed-out requirements can be satisfied and low-pressure measurement and outgoing line can be added as required by the customer
  • Strong in corrosion resistance due to special process treatment, made of ordinary steel sheet or stainless.
Applicable Place
  • Be applicable to the places without severe factors such as fire hazard, explosion risks, serious dirt, chemical corrosion and violent vibration, widely applied to outdoor power supply places such as cities, residential communities, hotels, hospitals, plants and mines, airports, railways and wharfs currently.

Product Details

DOWNLOAD



  • Model Description

  • Features
    • Small size, compact structure, only 1/3~1/5 of the domestic floor space of the same capacity
    • Fully insulated structure, safe and reliable.
    • Adopt low-loss, low-noise, strong overload capability S13 type transformer.
    • The power supply is flexible and reliable, and can be used for both ring and terminal.
    • To meet various low-voltage feed-out requirements, low-pressure metering and outlet can be added according to user requirements.
    • After special treatment, it has strong anti-corrosion ability and various shapes and structures. It can be made of ordinary steel plate and stainless steel.
  • Conditions of Use
    • Altitude: ≤1000m
    • Wind speed: ≤35m/S (not more than 700pa)
    • Ambient temperature: maximum temperature +40 ° C, minimum temperature -35 ° C
    • Relative humidity: daily average is not more than 90%, monthly average is not more than 95%
    • Shockproof: horizontal acceleration is not more than 0.4m/s2
    • Vertical acceleration is not more than 0.15m/s2
    • Installation site inclination: no more than 3°
    • If the above conditions are exceeded, you can negotiate with the company.

  • Technical parameters
  • S/N

    Item

    Unit

    Technical parameters

    l

    Main body of the transformer

    Rated voltage of high-voltage side

    1010.5

    2

    Rated voltage of low-voltage side

    0.4

    3

    Rated capacity

    30-2500

    4

    Wiring method

    Dynll, Yzn11, Yyn0

    5

    Rated frequency

    50

    6

    Voltage regulation tap switch

    ±5 ±2x2.5%

    7

    Noise level

    National Standard

    8

    Temperature rise of the oil level

    ≤55

    9

    Power frequency withstand voltage for lmin

    High-voltage side

    35

    55

    Low-voltage side

    5

    10

    Lightning impulse withstand voltage (peak)

    Full wave

    75

    125

    Chopped wave

    85

    140

    11

    Cooling mode

    Oil-immersed self-cooling

    12

    High voltage load switch

    Rated voltage

    12

    24

    13

    Rated current

    315/630

    14

    Rated short-time withstand current (4S)

    20/16

    15

    Rated short-circuit making current

    50/40

    16

    Full-load breaking times

    100

    17

    Mechanical life

    Times

    2000




Leave A Message

Name*

Phone*

Mailbox*

Content*

在线客服